Method For The Determination Of The Original Grain Size Of Pseudoboehmite
Dec 07, 2022
Pseudoboehmite can meet the requirements of homogeneous dispersion of oxygen source and reaction mixture, and is the first choice of aluminum source for experiments. So what is the original grain size determination method of quasi-boehmite? Today, Yangzhou Zhongtianli shares it with you and takes a look
1. Grinding method
This approach was mentioned by Alcoa's colleagues when they visited China earlier in the year. The particle size distribution and median diameter D50 of the crushed material were measured with a particle size analyzer at a specific volume, a certain ratio of material to ball and a fixed grinding time, and macroscopic control was achieved with this method.
2. X-ray diffraction method
The main method is the spectral linewidth method, which can measure the particle size of the quasi-bauxite, but the diffraction lines of the A-alumina powder series products are narrow and sharp. Experiments showed that there was no "money effect", and even the intensity of the diffraction peak was not consistent with the JCPDS card due to the influence of the mineralization agent, which further affected the accuracy of the quantitative analysis of alumina.
3, nitrogen adsorption small ratio surface methodIt is suitable for porous active substances, but because the sintered A alumina powder obtained at high temperature is dense, with few open and closed pores, it is difficult for liquid nitrogen molecules to enter the intergrain gap, so the measurement range is limited, and the measurement grain size error is large. The principle of this method restricts its industrial application value.4. Electron microscopyThe method of chemical etching combined with SEM to measure grain size is intuitive and reliable, and is an effective way to reflect grain shape and size, but it requires a lot of equipment and analysis.5, infrared spectrum structure analysis methodSince the size of the spectral absorption band is related to the grain size, an absorption band area integrator can be introduced into the structure of the IR spectrometer to calculate the average grain size. The amount of supply analyzed by this method is small, and it is still objectively difficult to obtain representative samples for samples with a wide range of particle size distribution.Considering the requirement of uniform dispersion of the reaction mixture, the added aluminum source can be dissolved in weak acid or medium strength acid solution. The above is Yangzhou Zhongtianli to share with you the related content of quasi-boehmite. I hope the above content will be helpful to you.